DACHELEMENTE


Pitched roof

Wir stellen Beispiele für Platten struktur basierend auf skandinavischen Baustandards. Jedoch können wir immer unsere Baunormen entsprechend nach dem Land, in dem wir arbeiten, anpassen.

PITCHED ROOF PANELS

300 mm THERMAL INSULATION
U < 0.12 W/m2K

CHOSEN ROOFING TYPE (mounted after assembling)
(ceramic / concrete tiles, metal roofing)
45 mm TIMBER LATHING
25 mm AIR GAP / TIMBER LATHING
WIND INSULATION – DIFFUSION MEMBRANE
245 mm TIMBER RAFTERS
250 mm THERMAL INSULATION
0,2 mm VAPOR BARRIER – STABILIZED FILM
45 mm TIMBER LATHING
42 mm INTERNAL LAYER OF THERMAL INSULATION / SPACE FOR ELECTRICAL CABLES
12,5 mm GYPSUM BOARDS FOR INTERIOR FINISHING (mounted after assembling)


Flat roof panels

FLAT ROOF PANELS

350 mm THERMAL INSULATION
U < 0.12 W/m2K

BITUMEN ROOFING (installed after assembling)
22 mm DURELIS BOARDS
45 / 145 mm VENTILATED AIR GAP – SLOPE FORMING TIMBER LATHS
WIND INSULATION – DIFFUSION MEMBRANE
0,2 mm VAPOR BARRIER – STABILIZED FILM
45 mm TIMBER LATHING
50 mm LAYER OF THERMAL INSULATION
245 mm TIMBER RAFTERS
250 mm THERMAL INSULATION
0,2 mm VAPOR BARRIER – STABILIZED FILM
45 mm TIMBER LATHING
42 mm INTERNAL LAYER OF THERMAL INSULATION 
12,5 mm GYPSUM BOARDS FOR INTERIOR FINISHING (mounted after assembling)